Part Number Hot Search : 
TK71340 CXA1845Q 236S1 20STI 2SC4007 AD676 32300 P4SMA36A
Product Description
Full Text Search
 

To Download LXR1240-6M1 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 X Series
375 and 500 Watt AC-DC Converters
Input range 85...264 V AC with PFC 1 or 2 isolated, regulated outputs up to 96 V 3 kV AC I/O electric strength test voltage
LGA
* Electrically and mechanically rugged DIN-rail front end * Outputs individually controlled with 150% output peak power * Operating ambient temperature range -40...60C with convection cooling
Selection chart for front ends
Output 1 Uo nom Io nom [V DC] [A] 24.7 15 24.7 20 37 9.9 37 13.2 49.4 7.5 49.4 10 24.7 10 49.4 5 Output 2 Uo nom Io nom [V DC ] [A] 24.7 10 49.4 5 Input voltage Ui min...Ui max Rated power TA = 60C Po tot [W] 375 500 375 500 375 500 500 500 Type Options1
85...264 VAC (14...440 Hz)3 90...350 VDC
LXR 1601-6 LXN-1601-6 LXR 1701-6 LXN 1701-6 LXR-1801-6 LXN-1801-6 LXN-2660-6 LXN 2880-6
R D1...D5 S M2 F, F1 K2
Selection chart for Battery chargers 2
Output Input voltage Rated power Type Options1 Uo nom Io nom Ui min...Ui max TA = 60C [V DC] [A] Po tot [W] 25.7...29.3 12.6 85...264 VAC 345 LXR 1240-6 M1 F, F1 25.7...29.3 16.9 460 LXN 1240-6 M1 K2 (14...440 Hz)3 51.4...58.6 6.3 90...350 VDC 345 LXR 1740-6 M1 51.4...58.6 8.4 460 LXN 1740-6 M1 1 For lead times and minimum order quantities contact Power-One. 2 For availability contact Power-One. 3 Input frequency range certified for 14...440 Hz. For continuous operating frequency <40 Hz and >100 Hz contact factory.
www.power-one.com
Edition 5/7.2001
1
X Series
Input
Input voltage Input frequency Power factor Inrush current
375 and 500 Watt AC-DC Converters
world wide mains, single phase for derating information see application note wide frequency range active PFC virtually no inrush current 85...264 V AC 90...350 V DC 16 2/3...440 Hz up to 0.99
Output
Efficiency Output voltage setting accuracy Output voltage noise Output voltage ripple Line and cross regulation Load regulation Minimum load Current limitation Short term peak power Operation in parallel Hold-up time
Ui nom, Io nom up to 89% Ui nom, Io nom 1.3% Uo nom IEC/EN 61204 typ. 50 mV sinusoidal output ripple at twice the line frequency 1.2 Vpp Ui min...Ui max typ. 50 mV 0...100 % Io nom, Ui nom -1.6% Uo nom not required rectangular U/I characteristic 101...112% Io nom 1 s, electronically controlled 150% Io nom enabled by droop current share Io nom, Uo decreases to 80% of Uo nom typ. 15 ms
Control
Status indication LED output(s) OK
Protection
Input reverse polarity Input fuse Input undervoltage lockout Input overvoltage lockout Input transient Output(s) Output overvoltage Overtemperature bridge rectifier not user accessible 10 A, fast blow typ. 80% Ui min typ. 105% Ui max
voltage depending resistor (VDR) no-load, overload and short circuit proof second control loop, each output, 24/48 V reduced output power if thermally overloaded
30/60 V SELV
Safety
Approvals in progress Electric strength test voltage EN 60950, UL 1950, CSA22.2 No. 950, UL 508 listed class I, I/case class I, I/O class I, O/case class I, O/O AC-in / DC-in 2 kV AC 3 kV AC 1 kV AC 0.35 kV AC 3/2 IP 20
Pollution degree Degree of protection
www.power-one.com
Edition 5/7.2001
2
DIN Rail Mountable
EMC
Electrostatic discharge Electromagnetic field Electr. fast transients/bursts Surge IEC/EN 61000-4-2, IEC/EN 61000-4-3, IEC/EN 61000-4-4, IEC/EN 61000-4-5,
X Series
level 4, contact/air (8/15 kV) criterion A level 3 (10 V/m) criterion A level 4, capacitive/direct (4/2 kV) criterion A level 3, in and out, line to line (2 kV) criterion B level >3, input, line to case (3.5 kV) criterion B level 2, output, line to case (1 kV) criterion A IEC/EN 61000-4-6, level 3 (10 V) criterion A CISPR 22/EN 55022, conducted class B
Conducted disturbances Electromagnetic emissions
Environmental
Operating ambient temperature Operating case temperature TC Storage temperature Damp heat Shock and vibration Shock Bump Vibration, sinusoidal Vibration, random MTBF
Ui nom, Io nom, convection cooled Ui nom, Io nom non operational IEC/EN 60068-2-3, 93%, 40C unit wall mounted with brackets IEC/EN 60068-2-27, 11 ms IEC/EN 60068-2-29, 11 ms IEC/EN 60068-2-6, 10...60/60...2000 Hz IEC/EN 60068-2-64, 20...500 Hz MIL-HDBK-217E, GB, 40C
-40...60C -40...87C -40...100C 56 days 50 gn 25 gn 0.35 mm/5 gn 0.05 g2/Hz 400'000 h
Options
Input and output undervoltage monitoring Output voltage adjustment 10 V...110% of Uo nom Remote on/off Multi option choice (D1...D5, R, S) via Sub-D connector Built-in second input fuse in the neutral No fuse fittet (for operation from high DC) System connectors with screw terminals D1...D5 R S M1...M2 F F1 K2
www.power-one.com
Edition 5/7.2001
3
X Series
Mechanical data
375 and 500 Watt AC-DC Converters
European Projection
Tolerances 0.3 mm (0.012") unless otherwise indicated.
15 (0.59")
204 (8.03") ( ) 196 (7.71") ( ) 194 (7.64") ( ) 29.4 (1.16")
113.6 (4.47") 106.6 (4.2")
S09127
138 (5.43") 5
Option M
13 (0.51") )
31 (1.22") TA Wall mounting brackets (accessory) TA
Measuring point for case temperature TC
43 (1.69")
www.power-one.com
Edition 5/7.2001
4
49 (1.93")
33 (1.3")
DIN Rail Mountable
Terminal allocation input side
Pin 1 2 3 Des. N P Determination Protective earth Input neutral I
S10066
X Series
n
1
2
3
Terminal allocation output side
Pin 1 2 3 4 5 6 7 8 9 10 11 12 Des. + + - - + + - - Aux1 Aux2 Single output Earth to load Output pos. Output pos. Output neg. Output neg. Output pos. Output pos. Output neg. Output neg. Options Options Earth to load Double output Earth to load Output 1 pos. Output 1 pos. Output 1 neg. Output 1 neg. Output 2 pos. Output 2 pos. Output 2 neg. Output 2 neg. Options Options Earth to load
S90048
1 2 3 4 5 6 7 8 9 10 11 12
Accessories
Mounting brackets for vertical chassis/wall mounting Protective covers over input and output terminals
www.power-one.com
Edition 5/7.2001
5


▲Up To Search▲   

 
Price & Availability of LXR1240-6M1

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X